Details, datasheet, quote on part number: TRIO-PS/1AC/24DC/10
Part | TRIO-PS/1AC/24DC/10 |
Category | Switches & Relays => Switches => Accessories |
Title | POWER SUPPLY DIN RAIL 24VDC 1P 10A |
Description | |
Company | Phoenix Contact |
Datasheet | Download TRIO-PS/1AC/24DC/10 datasheet |
Specifications | |
Accessory Type | DIN Rail Power Supply Unit |
For Use With | Process Control Equipment & Industrial Applications |
PHOENIX CONTACT Ltd Page 1 / 6 20-Jan-2012 Extract from the online catalog TRIO-PS/ 1AC/24DC/10 Order No.: 2866323. Power supply unit - TRIO-PS/1AC/24DC/10 - 2866323 Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's. Phoenix contact TRIO-UPS-2G/1AC/24DC/10 Pdf User Manuals. View online or download Phoenix contact TRIO-UPS-2G/1AC/24DC/10 Manual. Documentation for AC to 24V DC Converter rated to 240 Watts. A switch mode power supply for regulated power output. High efficiency.
Features, Applications |
DIN rail power supply unit, primary-switched mode, 1-phase, output: 10 A Pack Customs tariff Country of Origin Catalog page information 85044081 CN Page 591 (IF-2011) Please note that the data given here has been taken from the online catalog. For comprehensive information and data, please refer to the user documentation at http:// www.download.phoenixcontact.com. The General Terms and Conditions of Use apply to Internet downloads. Product description TRIO POWER is the DIN-rail-mountable power supply unit with basic functions. With an output voltage 5 V DC, 12 V DC, 24 V DC, and V DC and 1- and 3-phase versions with it is particularly suited for use in series production in mechanical engineering. The wide-range input and international certification package allow worldwide implementation. The high MTBF 500,000 h stands for high supply reliability. The devices can be connected in parallel to increase the capacity and redundancy. The clear LED signaling and the device connection with double terminal block for plus and minus for fast potential distribution are further advantages of this device series. A third minus terminal block simplifies the grounding on the secondary side. All power supply units are idle-proof and short-circuit-proof and provide a regulated and adjustable output voltage. Technical data Input data Nominal input voltage AC input voltage range Short-term input voltage AC frequency range Current consumption Inrush surge current Power failure bypass Input fuse Permissible backup fuse Power factor (cos phi) Type of protection Protective circuit/component Output data Nominal output voltage Setting range of the output voltage Output current Derating Connection in parallel Connection in series Max. capacitive load Current limitation Control deviation 22.5 V DC.. 24 V constant capacity) 55°C) 55 °C.. °C (2.5%/K) Yes, for redundancy and increased capacity Yes Unlimited Approx. 14 A (for short-circuit) 1 % (change in load, static (change in load, dynamic (change in input voltage ±10%) Residual ripple Peak switching voltages nominal load Maximum power dissipation idling Power loss nominal load max. < 10 mVPP < 50 mVPP 100 V AC.. 85 V AC.. V AC (derating 90 V AC: 2.5% per Kelvin) AC 45 Hz.. (100 V AC) (240 V AC) (120 V AC) (230 V AC) 6.3 A (slow-blow, internal) B16 0.99 Transient surge protection Varistor General data Width Height Depth Net weight Operating voltage display Efficiency Insulation voltage input/output Degree of protection Protection class MTBF (IEC SN 29500) Ambient temperature (operation) Ambient temperature (storage/transport) Max. permissible relative humidity (operation) Mounting position Assembly instructions Electromagnetic compatibility Noise immunity Low Voltage Directive Standard Electrical equipment of machines Standard - Safety of transformers Standard - Electrical safety Standard Electronic equipment for use in electrical power installations and their assembly into electrical power installations Standard Safety extra-low voltage Standard - Safe isolation Standard Protection against electric shock Standard Protection against shock currents, basic requirements for protective separation in electrical equipment Standard Limitation of mains harmonic currents 1.4 kg Green LED 89 % (for V AC and nominal values) kV AC (type test) kV AC (routine test) IP20 I, with PE connection h -25 °C.. 55° C derating) -40 °C.. 95 % (at 25 °C, no condensation) horizontal DIN rail EN 60715 Can be aligned: Horizontally 0 mm, vertically 50 mm Conformance with EMC Directive EN 61000-6-2:2005 Conformance with LV directive 60950-1/VDE 0805 (SELV) 50178/VDE 0160 (PELV) |
Trio-ps 1ac 24dc 10 User Manual Download
Same catergory |
17G715GF2 : EARTH LEAKAGE RELAY, 110-240VAC. s: Contact Configuration: - ; Power Consumption: 5VA ; Supply Voltage Max: 240VAC ; Supply Current Max: - ; Relay Mounting: DIN Rail ; Series: CMR. 157-22T200 : POWER RELAY, DPDT, 120VAC, 10A, PLUG IN. s: Relay Type: General Purpose ; Contact Current Max: 10A ; Contact Voltage AC Nom: 600V ; Contact Voltage DC Nom: 28V ; Coil Resistance: 2.25kohm ; Coil Type: AC ; Coil Current: - ; Nom Operating Power: 1.7VA ; Contact Configuration: DPDT ; Relay Mounting: Plug In ; External Height: 48.38mm ; Coil Voltage VAC Nom:. SIM212-12VDC : SAFETY RELAY, 2NO/1NC, 12V, 8A. s: Coil Voltage VAC Nom: - ; Coil Voltage VDC Nom: - ; Coil Resistance: - ; Contact Current Max: - ; Contact Voltage AC Nom: - ; Contact Voltage DC Nom: - ; Contact Configuration: - ; No. of Poles: - ; Relay Mounting: - ; External Height: - ; External Width: - ; External Depth: -. SF2-24V : RELAY, FORCED CONTACT, DPCO, 24VDC. s: Coil Voltage VAC Nom: - ; Coil Voltage VDC Nom: 24V ; Coil Resistance: 1.152kohm ; Contact Current Max: 6A ; Contact Voltage AC Nom: 250V ; Contact Voltage DC Nom: 30V ; Contact Configuration: DPCO ; No. of Poles: 2 ; Relay Mounting: PCB ; External Height: 53.3mm ; External Width: 25mm ; External Depth: 16.5mm. RJ1A23A50U : SSR, DIN RAIL, 265VAC, 275VAC/48VDC, 50A. s: Control Voltage Range: 24VAC to 275VAC / 24VDC to 48VDC ; Operating Voltage Range: 24VAC to 265VAC ; Load Current: 50A ; Switching Mode: Zero Crossing ; Relay Terminals: Cage Clamp ; Contact Configuration: SPST. AQW212 : SSR, PHOTO MOSFET, 60V, 500mA. s: Load Voltage Max: 60V ; Load Current: 500mA ; On State Resistance Max: 2.5ohm ; Contact Configuration: DPST-NO ; Isolation Voltage: 1.5kV ; Forward Current If: 900µA ; Relay Terminals: Through Hole ; MSL: -. AQY272A : PHOTOMOS RELAY, 60V, 2A. s: Load Voltage Max: 60V ; Load Current: 2A ; On State Resistance Max: 0.18ohm ; Contact Configuration: SPST-NO ; Isolation Voltage: 2.5kV ; Forward Current If: 1mA ; Relay Terminals: SMD ; MSL: -. B32-1230 : Keycap. s: For Use With: Omron B3F And B3W Series Tactile Switches ; Actuator / Cap Color: Yellow. UC-300L : Replacement Lens. s: Mounting Hole Dia: - ; For Use With: Banner SM2A312D Series Sensor ; Lens Width: - ; Lens Color: - ; Lens Height: - ; Lens Diameter: -. ZB5-AZ905 : BEZEL TOOL. s: For Use With: -. Harmony® style 5 Pushbuttons, switches and pilot lights, with double insulated bezel The Ø 22, style 5 range of control and signalling units comprises: Pushbuttons and switches: Head and body sub-assemblies Pilot lights: Head and body sub-assemblies Emergency stop latching mushroom head. Push-pull Emergency stop trigger action mushroom head Push-pull. MINI-PS-48-60DC/24DC/1 : DC-DC DIN RAIL IP48-60VDC OP24VDC 1A. s: Accessory Type: DC/DC Converter ; For Use With: Process Control Equipment & Industrial Applications. 531-SWHOX : SWITCH, FOOT, SPDT, (ON), 20A, 250V. s: Contact Configuration: SPDT ; Contact Voltage AC Nom: 250V ; Contact Voltage DC Nom: - ; Contact Current Max: 20A ; Switch Operation: (On) ; External Height: 146.8mm ; External Width: 153.19mm ; External Depth: 231.9mm. 6289-CC : FOOTSWITCH. s: Contact Configuration: SPCO ; Contact Voltage AC Nom: 250V ; Contact Voltage DC Nom: - ; Contact Current Max: 3A ; Switch Operation: - ; External Height: 89mm ; External Width: 63mm ; External Depth: 89mm. 96AB2-102-R : SWITCH, KEYPAD, 3X4, 5mA, 12V, ABS. s: Keypad Array: 3 x 4 ; Contact Voltage AC Nom: - ; Contact Voltage DC Nom: 12V ; Contact Current Max: 5mA ; Keypad Output: Matrix ; Panel Cutout Width: 50.8mm ; Panel Cutout Height: 71.12mm ; Housing Material: ABS ; Illumination Color: - ; No. of Keys: 12. OS102011MS2QN1 : SLIDE SWITCH, SPDT, 100mA, 12VDC. s: Contact Configuration: SPDT ; Actuator Style: Raised ; Switch Operation: On-On ; Contact Voltage AC Max: - ; Contact Voltage DC Max: 12V ; Contact Current Max: 100mA ; Switch Mounting: PCB ; Orientation: Vertical. |